It offers a complete turnkey solution for ambient light sensor calibration and test. Tunable light source use in handler is capable to provide uniform light from 300nm to 1100nm at 2nm steps or smaller for calibration, while sensor is tested with more than 10 types of white lights to emulate real life environment. Test coverage includes electrical, optical alignment, module light leakage, sensor sensitivity, and more.
Handler is designed with mass production operation in mind with high parallelism testing up to 108 sites and it comes with many excellent automated features such as Automated GRR, Automated Gold Module Monitoring, Automated Retest, Automated Yield Monitoring and Triggering, and many more.
Input/Output Option | JEDEC Tray |
Contact Mechanism | Punch Type |
Contact Type | Non-Kelvin |
Test Site | – Up to 36 sites – Up to 108 sites base on multi test cell configuration |
Tester Sequence | Parallel/Serial Test |
Spectral Range |
300nm~1100nm |
Tunable Light Source |
300nm~1100nm (Low Maintenance By Yearly) |
Test Capabilities | – Electrical Functional Test – Sensitivity Test – Optical Alignment Test – Light Leakage Test – Spectral Test – Calibration Test |
Intelligent Features |
– Automated GR&R |