PM63

 

PM6300 is an ambient and elevated temperature test handler designed to handle multiple test sites and vision inspection. This handler processes SOIC, SSOP, TSSOP, QFN and many other packages.

Features

  • Optional lead inspection module
  • Optional hot temperature test (55 -155 deg)
  • Optional output tape & reel module
  • Direct docking to tester
  • Capable to process a wide spectrum of packages
  • Compact in size

Product Specifications

PackagesSOIC, SSOP, TSSOP and QFN
MachineDimension (LxWxH) & Weight- 900 x 800 x 1700mm
- 750kg
Power220 VAC 50/60 Hz Single phase
AirMin. 5 bar / 70 psi
User Interface- Window base with GUI
- Full system diagnostic capability
Input Options- Tube stacker up to 35 tubes (live bug)
- bowl
Output Options- Tube stacker up to 35 tubes (live bug)
- Tape & Reel
Machine Performance UPHUp to 12,000 units with zero test time and zero reject
MTBA> 60 mins
MTBF> 200 hours
MTTR< 20 minutes
MTTA< 30 seconds
Vision Inspection Capabilities Vision Repeatability Accuracy0.5 mil
GR&R< 10 %
Lead InspectionLead quantity
Lead length
Lead width
Lead spacing
Lead tweeze / implied
Lead slant
Lead spread
Lead bridging (5>mil length)
Lead bent in / out
Test Specification
Test SitesDual or quad test sites
Test OptionsFunctional and / or open / short tests
Test Contactor Contact FingerPunch or clamp type
Contact Resistance< 0.2 Ohm per finger
Durability800k insertions
TemperatureTemperature RangeFrom room temperature to +60°C to 155°C
Accuracy±2°C at test sites, ±3°C at soak chamber & heated tracks
Temperature Rise TimeApprox 15 minutes (based on ambient to 135°C)
Additional Features- Oven temperature control
- User defined soak time
- Auto calculate offset value